A Missing Lactate Is Not a Normal Lactate
A coverage criterion is a set of testable conditions on documented values. Sepsis-3 states three: sepsis is suspected infection with an acute rise in the Sequential Organ Failure Assessment (SOFA) score of 2 points or more; septic shock adds a vasopressor holding mean arterial pressure at 65 mm Hg or greater and a lactate above 2 mmol/L, or 18 mg/dL (Singer et al., JAMA 2016;315(8):801-810). A validator reading a chart against those conditions returns one of five results, and the whole ethics of the thing sits between two of them: not met, and insufficient documentation. The federal inspector general found that where plans cited insufficient documentation, the records already in the file were sufficient, and that 13% of a sample of denied prior authorization requests met Medicare coverage rules (OIG, OEI-09-18-00260, April 2022). Six things from building a validator that refuses that mistake.
1. Absence of a value is never failure. Met: a documented value satisfies the condition. Not met: the values are there and none satisfies it. Insufficient documentation: the value is missing, unreadable or outside the window. Conflicting: two values at one time disagree. If a validator read silence as failure, every gap in a record would become a denial, and the person with the thinnest chart would lose. That is a medical-cost decision made by a parser.
2. When the value is absent, the validator stops and says why. The rule is settled: an algorithm may assist but may not itself be the basis of a medical-necessity denial (CMS Medicare Advantage FAQ, February 2024; California SB 1120, 2024). What matters here is what a validator does at the gap. Ours returns insufficient documentation, names the missing value, the window it looked in and the unit it expected, and hands that list to a person as a request for the record, not as a result. It does not substitute a default, it does not score the item as unmet, and it does not count the case in a denial rate. The only line it moves on its own is the cost of approving the cases where the values are present and met; the gap cases stay on a physician's desk, and that time is the administrative cost that stays.
3. Record your own call first. A validator that shows its answer first trains the reader to agree with it. The instrument withholds each result until the reviewer has recorded a call; a disagreement needs a one-line reason, and that line is the second read.
4. At 18.00 mg/dL the criterion is not met; at 18.01 it is. A value is compared with the threshold stated in the unit it was reported in, unconverted. Only when no threshold exists in that unit is a declared factor used, lactate mg/dL divided by 9.01, labelled "verify with the laboratory". A validator that rounds, or converts by an undeclared factor, has rewritten the policy.
5. The score is entered, never computed, and the composition is not the definition. Sepsis-3 does not say how suspected infection is documented or in what window a value counts. The instrument's windows, an antibiotic from 24 hours before to 72 hours after onset, labs from 6 hours before to 24 after, are labelled example compositions. Under 42 CFR 422.101(b) a plan may write internal criteria only where Medicare's are not fully established; a window written into a validator is such a criterion, and it belongs to whoever owns policy.
6. The one source has not been read by a person, and the page says so. The definitions carried are the three the abstract states; the SOFA component table is not carried; the authority tab prints that one of one sources is unverified. We could not price a sepsis validation program from this record, so the instrument prices nothing: no figure goes on the board.
We built these into an instrument: one worked policy, Sepsis-3, as five items; a values form that accepts pasted text; your call first, then the result with the values used and why; boundary cases evaluated live in each stated unit. It decides nothing. Synthetic values only.
A validator that turns silence into failure has denied the patient with the thinnest chart.
When your clinical validation vendor returns "not met", who in your building asks whether anybody wrote the value down?